Each Flowrox Knife Gate Valve is fully loaded and originally equipped with a flushing port, limit switch mounting, locking gate, and both top and bottom stem protectors.  Each Larox knife gate valve has a heavier thicker gate and a “J” ring seat design that is able to withhold higher pressures than the conventional “C” ring design.  Removable seats on both sides of the blade provide a bi-directional bubble tight seal in which absolutely no parts of the metal are exposed to slurry. 

Valve Operation

When a Larox Knife Gate Valve is in the open position the two sleeves seal against each other in the center, providing a full bore that allows the slurry to travel through without touching any metallic components.  When closing the valve, the gate is forced progressively downward as it nears the fully closed position.  At this point, the sleeves are sealed tightly against both sides of the gate so that the line pressure is completely and efficiently contained.

How the rubber sleeves work

In the valve housing there are two matching rubber sleeves that seal tightly against the gate when the valve is in the closed position and suction together when it is in the open position.  This tight seal provides the high internal line pressure, which, in combination with the double seated sleeve design, also permits perfectly tight shut-off.  There is a wide variety of sleeve materials available for different process needs. 

Secondary Seal

Larox Knife Gate Valves have elastomer secondary seals that replace the merely conventional gland packing.  These elastomer secondary seals perform both wiping and lubricating actions to the blade as it strokes down into the silicone filled grease contours of the seal itself.  This type of lubrication of the blade allows for easer actuation and movement.  The elastomer secondary seal’s lifespan is longer than competitors, but when a replacement is necessary, there is no need to remove the valve from the line.

Takaisin listaukseen

Contact presse
Tuija Tiilikainen
e-mail: tuija.tiilikainen(a)flowrox.com
mobile: +358 (0)45 878 3528






This website stores cookies on your computer. These cookies are used to improve our website and provide more personalised services to you.
Close

Cookies

To make this site work properly, we sometimes place small data files called cookies on your device. Most big websites do this too.

1. What are cookies?

A cookie is a small text file that a website saves on your computer or mobile device when you visit the site. It enables the website to remember your actions and preferences (such as login, language, font size and other display preferences) over a period of time, so you don’t have to keep re-entering them whenever you come back to the site or browse from one page to another.

2. How do we use cookies?

A number of our pages use cookies to remember your actions and preferences (such as login, language, font size and other display preferences.)

Also, some videos embedded in our pages use a cookie to anonymously gather statistics on how you got there and what videos you visited.

Enabling these cookies is not strictly necessary for the website to work but it will provide you with a better browsing experience. You can delete or block these cookies, but if you do that some features of this site may not work as intended.

The cookie-related information is not used to identify you personally and the pattern data is fully under our control. These cookies are not used for any purpose other than those described here.

3. How to control cookies

You can control and/or delete cookies as you wish – for details, see aboutcookies.org. You can delete all cookies that are already on your computer and you can set most browsers to prevent them from being placed. If you do this, however, you may have to manually adjust some preferences every time you visit a site and some services and functionalities may not work.

Close